特区性爱久久視频_91精品啪在线观看_亚洲在线免费高清_中文字幕国产精品视频在线 _91插插插影库永久免费 - 国产探花1-爱慕虚荣的Gucci小妹被爆操-赵总探花 _男女做暖的禁18国产大陆天天_黄片视频影院在线观看_中文字幕日韩永成精品_小黄片2020_91丨九色丨国产丨_强奸乱伦亚洲第一页_无码一区二区三区紧身裤_日韩性爱在线视频整片_影音先锋男人av鲁色资源久久_嗯啊人人操人人

2020 官網(wǎng)升級中!現(xiàn)在您訪問官網(wǎng)的瀏覽器設(shè)備分辨率寬度低于1280px
請使用高分辨率寬度訪問。

Consultation hotline:400-021-6779
The importance of variable frequency power supply to the protection of pulse group generator
Release time: 2018-08-03Views: 1,153

Many people should know about the pulse group generator, but they must have little knowledge about the variable-frequency power supply. In fact, the variable-frequency power supply plays a lot of roles in the protection of the pulse group generator. Today, I will tell you about the importance of this

Protection effect of variable frequency power supply on pulse group generator:

Apply the test voltage to the variable frequency power line through the fault connection / fault removal network. Apply the test voltage to the signal line and control line through the capacitor clamp. The pulse group generator test uses interference to charge the line junction capacitance. When the energy on the junction capacitance accumulates to a certain extent, it may cause errors in the line (or even the system). Therefore, there is a process of line error, and there is a certain contingency. It cannot be guaranteed that the error will occur at any interval, especially when the test voltage is close to the critical value. For this reason, some product standards stipulate that the test on the power line is conducted between the line and the ground. It is required to conduct three tests on one line under one test voltage polarity, one minute each time, with an interval of one minute: after one polarity is completed, change to another polarity. When one line is finished, change to another line. Of course, pulses can also be injected into two lines, or even several lines at the same time. Because the transmission process of the pulse group generator signal on the power line is very complex, it is difficult to judge whether to add pulses separately or together, and the equipment is more likely to fail. Therefore, adding pulses at the same time is only a form of experiment, and it is ultimately up to the experiment to draw a conclusion.

Other standards (such as gb4343.2) stipulate that 2min positive polarity pulse shall be added to one line first, and then 2min negative polarity pulse shall be added after a short rest. It can be seen that different standards have different provisions, but they all have a relatively long test process to avoid contingency. And expose hidden dangers through a variety of combinations. Usually, the test object is only sensitive to the test of one wire and one polarity.

Burst immunity test is a kind of test that is difficult to pass in all common immunity tests, and it is also a kind of test with poor repeatability and comparability. Therefore, in the description of this section, it is emphasized that the essence of this test is common mode test. Because the waveform contains rich harmonic components and high upper limit frequency, the standardization of the test is particularly important.

 

Share to
Return to list